1. Introduction

Welcome to the GRB Autonomous Awareness Systems (AAS) Design and Installation Guide. This guide serves as a comprehensive manual for professionals deploying AAS in the demanding environments of mining and industrial sectors. As a leader in providing innovative installation services, GRB is committed to setting new benchmarks in safety, performance, and operational efficiency. This document covers everything from power supply specifications to sophisticated network configurations and modular component integration. Our goal is to ensure every installation meets the highest standards, reflecting our commitment to quality and excellence in all operational scenarios.

2. Power Supply

2.1. Power Supply Requirements


  • Voltage and Amperage Specifications: The AAS requires a stable output of 5A at 24V for heavy-duty machinery or 5A at 12V for lighter vehicles. These specifications ensure consistent power delivery across all devices, maintaining optimal operation under varying load conditions and preventing performance degradation.


2.2. Power Conditioning


  • Clean Power Supply: A robust power conditioner is essential for filtering electrical noise and stabilizing voltage fluctuations. This equipment protects sensitive system components from potential damage due to spikes or voltage drops. It is designed to handle full load capacities efficiently, reducing power loss and extending the system's lifespan.


2.3. Fusing and Safety


  • Circuit Protection with Fuses: Fuses, rated no higher than 10 amps, must be installed to protect power supply circuits. These should be strategically positioned near the power source for swift fault detection and quick response. Proper fusing is crucial to prevent overloads and short circuits that could cause significant equipment damage or fires.

  • Overcurrent and Overvoltage Protection: Integrating overcurrent and overvoltage protection mechanisms is essential for safeguarding the system against unexpected power anomalies. Automatic disconnections help preserve system and operator safety during irregular power conditions.


2.4. Power Control and Safety Mechanisms


  • Operator-Controlled Power Switch: An operator-accessible, momentary-type power switch with safety features such as a locking cover or recessed design is necessary to prevent unintended activation.

  • Emergency Shutdown Capability: A fail-safe emergency shutdown feature allows the operator to immediately cut power to all AAS components, ensuring reliability under various power conditions.


2.5. Circuit Design for Reliability


  • Continuous Power Retention: Network devices, including radios and switches, are designed to retain power until all connected devices have been properly shut down. This prevents data corruption and facilitates a smooth transition to an off state.

  • Isolation and Surge Protection: Electrical isolation techniques, such as the use of isolation transformers and surge protectors, are employed to protect sensitive components from voltage surges, reducing the risk of internal and external disturbances.


2.6. Prohibited Practices and Best Practices


  • Avoid Direct Splicing from Vehicle Systems: Direct connections from vehicle battery lines that serve existing control modules (ECM/ECU) are discouraged to prevent interference and power disruptions.

  • No Use of Power Converters: The use of power converters is discouraged unless absolutely necessary. When required, converters must meet stringent standards for efficiency and reliability, including comprehensive filtering and regulation capabilities.


2.7. Grounding and Shielding Considerations


  • Effective Grounding Practices: Each component should be grounded independently from the vehicle chassis to minimize electrical noise and enhance system stability, avoiding ground loops.

  • Shielding Against Electromagnetic Interference (EMI): Power cables should be adequately shielded to protect against EMI from nearby components or external sources, ensuring data integrity and reliable system communication.


3. High Precision GPS Receivers Detached

3.1. Modular and Strategic Design


  • Dedicated Mounting Posts: GPS receivers are mounted on dedicated posts, separate from the main system enclosure, to prevent potential signal interference from the vehicle’s or machinery’s metal structures. This positioning ensures a clear line of sight to satellites, which is crucial for maintaining high positional accuracy.

  • Modular Configuration: The modular nature of the GPS setup allows for flexible installation options based on the specific needs of the site and equipment. This design supports easy upgrades and maintenance without compromising system integrity.


3.2. Enhanced Signal Integrity


  • Advanced Signal Processing: The GPS receivers are equipped with advanced signal processing capabilities to enhance reception in challenging conditions, such as under dense canopy or near tall structures where signal reflection and diffraction may occur.

  • Multi-Frequency Receivers: Multi-frequency GPS receivers are used to access multiple satellite signals simultaneously. This capability significantly improves accuracy and reliability, mitigating the impact of ionospheric disturbances on signal quality.


3.3. Integration with Other Systems


  • Seamless System Integration: GPS receivers are designed to integrate seamlessly with other components of the Autonomous Awareness Systems, providing critical location data for navigation, mapping, and operational analytics.

  • Data Synchronization: Positional data from GPS receivers is synchronized in real-time with other system data streams, enhancing the functionality of operational monitoring and control systems.


3.4. Reliability and Redundancy


  • Built-In Redundancy: To ensure continuous operation, multiple GPS receivers can be deployed to provide redundancy. If one receiver encounters a signal issue, others can maintain system accuracy and functionality.

  • Robustness Against Environmental Factors: Each receiver is housed in a protective enclosure to shield it from environmental factors such as dust, moisture, and mechanical vibrations, ensuring long-term reliability.


3.5. Technical Specifications and Compliance


  • High-Accuracy Standards: The GPS receivers used comply with stringent accuracy standards, capable of delivering sub-meter precision necessary for detailed industrial applications.

  • Regulatory Compliance: All GPS components meet global navigation satellite system (GNSS) standards and local regulations, ensuring they can be deployed across various regions without compatibility issues.


4. Enclosure Mounting and Configuration

4.1. Enclosure Mounting Requirements


  • External Mounting Requirements: Enclosures are mounted externally to facilitate direct connections with both internal and external components, minimizing potential signal degradation.

  • Modular Design Considerations: Inputs and outputs are organized through designated termination panels or bulkhead groups to support diverse configurations and streamline cable management.


4.2. Construction Standards


  • Material Specifications: Enclosures are made from grade 316 stainless steel, ensuring a minimum thickness of 1.5 mm for both the body and door, providing robust durability and environmental protection.

  • Heat Dissipation Requirements: The design includes effective thermal management to maintain internal component temperatures below 70°C, even under direct sunlight.


5. Operator Display Requirements


  • Display Positioning: The operator display is positioned for optimal visibility without obstructing essential views or controls, complying with Australian Design Rules (ADR) for safety and visibility.

  • Safety Considerations: The display is designed to account for operational risks and potential accidents, ensuring it does not hinder the operator’s movements or cab access.


6. Network Hardware and Configuration

6.1. Network Architecture


  • Advanced Equipment: The network setup includes high-performance Ethernet switches, routers, and wireless access points, chosen for their reliability and effectiveness in industrial settings.

  • Redundancy and Failover: The network design incorporates redundancy for critical components to ensure continuous operation. This failover capability maintains functionality without data loss or communication interruptions in the event of a hardware failure.

  • Scalability: The network infrastructure is designed to be scalable, allowing for easy expansion and integration as operational needs evolve, without disrupting existing operations.


6.2. Power Over Ethernet (PoE)


  • Integrated PoE Support: Network devices are equipped to support PoE standards IEEE 802.3af and IEEE 802.3at, ensuring compatibility with a wide range of industrial devices.

  • Energy Efficiency: PoE contributes to energy efficiency by eliminating the need for separate power supplies for each device, reducing the system's overall power consumption.


6.3. Network Security


  • Advanced Security Protocols: The latest security measures, including end-to-end encryption, secure authentication methods, and continuous updates, are implemented to protect against evolving threats.

  • Network Monitoring and Management: Continuous monitoring of network activity enables immediate detection and response to unauthorized access or anomalies, maintaining system security and performance.


6.4. Device Setup and Configuration


  • User-Friendly Interfaces: Devices feature user-friendly interfaces for easy setup and management of network settings.

  • Automated Configuration Tools: Automated tools simplify the initial setup and subsequent configuration changes, reducing human error and ensuring consistent network performance.


6.5. Compliance and Standards


  • Industry Compliance: Adhering to standards such as IEEE for network hardware and various industrial protocols ensures compatibility with other industrial technology and compliance with regulatory requirements.

  • Certifications: All network components are certified for use in industrial environments, meeting rigorous testing standards for durability, reliability, and safety.


7. Electrical Cabling and Connectors

7.1. Cable Specifications


  • High-Conductivity Cables: Only high-conductivity, shielded copper cables are used to minimize electromagnetic interference (EMI) and maintain signal integrity in environments with high electrical noise.

  • Durability Under Stress: Cables are designed to withstand harsh environmental conditions, including moisture, dust, and temperature variations, ensuring long-term performance.

  • Heat and Stress Avoidance: Cables are routed away from heat sources and mechanical stress points to extend their lifespan and reduce performance risks.


7.2. Splicing and Termination


  • Minimized Splicing: Splicing is minimized to maintain signal integrity and reduce potential points of failure. When splicing is unavoidable, connections are made with precision to ensure secure and stable electrical continuity.

  • Robust Soldered Joints: Connections are reinforced using robust soldered joints, which are then protected with dual-wall heat shrink tubing. This provides additional protection against environmental damage and ensures a secure, long-lasting electrical connection.


7.3. Connector Specifications


  • IP66 Rated or Higher: All connectors used in the AAS installations meet or exceed IP66 ratings, providing complete protection against dust ingress and high-pressure water jets. This high level of protection is crucial for maintaining system functionality in all weather conditions.

  • Self-Locking Mechanisms: Connectors are designed with advanced self-locking mechanisms to prevent accidental disconnections, which could lead to system failures or pose safety risks.

  • Design and Compatibility: Each connector is carefully selected and designed to meet the unique electrical and signal requirements of the AAS. This includes ensuring compatibility with a variety of industrial equipment and compliance with international electrical standards.


7.4. Cable Routing and Protection


  • Predefined Pathways: Cables are routed through predefined pathways to avoid areas prone to damage or high risk. This strategic planning helps prevent mechanical damage and prolongs cable life.

  • Securing and Protection: Cables are secured using a combination of cable ties, clamps, and protective conduits, particularly in high-risk areas. These protective measures enhance durability and reduce the risk of damage due to environmental factors or mechanical wear.


8. Bracketry and Fasteners

8.1. Bracket Design


  • Durability and Strength: Brackets are designed to support the operational lifespan of the equipment, using materials that can withstand environmental and operational stresses without degradation. This includes resistance to corrosion and mechanical fatigue.

  • Custom Engineering: Each bracket is custom-engineered to fit specific applications, ensuring a secure and stable mounting solution tailored to the equipment and installation environment.


8.2. Fastener Standards


  • High-Strength Fasteners: Metric fasteners with a minimum tensile strength of 10.9 are employed to ensure secure and reliable assembly. These fasteners provide high resistance to shear and tensile forces, which is critical in demanding operational environments.

  • Hardened Flat Washers: Hardened flat washers are used instead of spring washers to maintain a secure and durable assembly over time. This prevents loosening under vibration or stress.


9. Compliance and Safety Considerations

9.1. Adherence to Standards


  • Industry Standards Compliance: All installation and operational procedures comply with AS3990 mechanical equipment standards, as well as original equipment manufacturer (OEM) guidelines. This adherence ensures that all systems are installed safely, reliably, and efficiently.

  • Internal Safety Protocols: GRB follows rigorous internal safety protocols during installation to maintain high-quality standards and ensure the safety of personnel and equipment.


9.2. Quality Assurance


  • Regular Inspections and Testing: To ensure installations meet safety and quality standards, regular inspections and testing are conducted. These checks help identify potential issues early and ensure ongoing compliance with industry regulations.

  • Continuous Improvement: Feedback from installations is continuously analyzed to improve practices and protocols, ensuring that GRB remains at the forefront of installation quality and safety.